Assessment of Long-Acting Reversible Intrauterine Contraceptives by using HDlive Technique

LE Machado, F Raga, F Bonilla, Fernando Bonilla-Musoles, JC Castillo, O Caballero, MJ Esquembre

Keywords : Copper T,Mirena,Ancora IUDs,Three-dimensional,HDlive

Citation Information : Machado L, Raga F, Bonilla F, Bonilla-Musoles F, Castillo J, Caballero O, Esquembre M. Assessment of Long-Acting Reversible Intrauterine Contraceptives by using HDlive Technique. Donald School J Ultrasound Obstet Gynecol 2014; 8 (3):273-277.

DOI: 10.5005/jp-journals-10009-1365

License: CC BY-NC 4.0

Published Online: 01-06-2015

Copyright Statement:  Copyright © 2014; The Author(s).


Abstract

How to cite this article

Bonilla-Musoles F, Raga F, Caballero O, Esquembre MJ, Bonilla F Jr, Castillo JC, Machado LE. Assessment of Long-Acting Reversible Intrauterine Contraceptives by using HDlive Technique. Donald School J Ultrasound Obstet Gynecol 2014;8(3):273-277.


PDF Share
  1. Precision intrauterine contraception may significantly increase continuation of use: a review of long-term clinical experience with frameless copper-releasing intrauterine contraception devices. Int J Women's Health 2013;5:215-225.
  2. com (webpage on the Internet). Teen pregnancy rates in the USA 2011. Available at: http://www.livestrong.com/ article/12504-teen-pregnancy-rates-usa‥
  3. Width of the normal uterine cavity in premenopausal women and effect of parity. Obstet Gynecol 2010;116(2pt 1):305-310.
  4. Three-dimensional ultrasound detection of abnormally located intrauterine contraceptive devices which are the source of pelvic pain and abnormal bleeding. Ultrasound Obstet Gynecol 2009;34(1):110-115.
  5. Does the type of intrauterine device affect conspicuity on 2D and 3D ultrasound? Am J Roentgenol 2011;196(6):1439-1443.
  6. Three-dimensional power Doppler study of endometrial and subendometrial microvascularization in women with intrauterine device-induced menorrhagia. Fertil Steril 2013;99(7):1912-1915.
  7. Intrauterine device failure: relation to its location within the uterine cavity. Obstet Gynecol 1993;81(1):112-114.
  8. How accurate is ultrasonography in monitoring IUD placement? J Clin Ultrasound 1990;18(5):395-399.
  9. Control of intrauterine device insertion with three-dimensional ultrasound: is it the future? J Clin Ultrasound 1996;24(5):263-267.
  10. Ecografía vaginal Doppler y tridimensional. Capítulo 39. El dispositivo intrauterino pp 689-699. Panamericana Ed. Madrid. 2004. ISBN: 8479035668.
  11. Use of three-dimensional ultrasound in evaluating the intrauterine position of a levonorgestrel-releasing intrauterine system. Reprod Biomed Online 2007;14(4):495-497.
  12. Three-dimensional ultrasound imaging of an intrauterine device showing copper corrosion. Ultrasound ObstetGynecol 2013;42(5):603-607.
  13. Antikonzeption-Wo der Ultraschall massgeblich unterstützt Praxis 2013;102(12):713-719.