REVIEW ARTICLE | https://doi.org/10.5005/jp-journals-10009-1714 |
Superb Microvascular Imaging Assessment of Placenta Using an 18-MHz Probe
1,4Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan; Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Kagawa, Japan
2,3Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan
5,6Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Kagawa, Japan
Corresponding Author: Toshiyuki Hata, Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan; Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Kagawa, Japan, Phone: +81-(0)87-891-2174, e-mail: toshi28@med.kagawa-u.ac.jp
How to cite this article Hata T, Koyanagi A, Takayoshi R, et al. Superb Microvascular Imaging Assessment of Placenta Using an 18-MHz Probe. Donald School J Ultrasound Obstet Gynecol 2021;15(3):312–322.
Source of support: Nil
Conflict of interest: None
ABSTRACT
Superb microvascular imaging (SMI) can detect low-velocity blood flow in the placenta by significantly reducing motion artifacts. Moreover, SMI using an 18-MHz probe generates a high-resolution image of the placental microvasculature in normal and abnormal placentas. In the normal placenta, the increased density of the placental microvasculature with advancing gestation was evident using SMI with an 18-MHz probe. The placental baseline between the placenta and myometrium was also clearly identified. In the first-trimester placenta with an extremely large subchorionic hematoma, decreased vascularity in the placenta adjacent to the hematoma was clearly recognized. In the circumvallate placenta, the placental microvasculature using 18-MHz-SMI was more precisely noted compared with conventional SMI. In a case of pregnancy after a previous uterine fundal incision, a high-resolution SMI with an 18-MHz probe could clearly identify the very thin uterine wall. In cases of placenta accreta spectrum (PAS) during pregnancy and in the retained placenta after birth, various types of PAS were noted, and unique microvasculature was also demonstrated using SMI with an 18-MHz probe. Superb microvascular imaging with an 18-MHz probe may become a future modality to provide novel information on the antenatal evaluation of normal and abnormal placentas, and the physiologic progress of normal placental microvascular development, and precise pathologic findings of placental abnormality in clinical practice and future research.
Keywords: 18-MHz probe, Circumvallate placenta, Placenta, Placenta accreta spectrum, Retained placenta, Superb microvascular imaging, Subchorionic hematoma, Uterine fundal incision.
INTRODUCTION
The novel Doppler modality of superb microvascular imaging (SMI) (Aplio i800; Canon Medical Systems, Tokyo, Japan) uses an algorithm that minimizes motion artifacts by filtering out tissue motion (clutter), and it can be used to visualize low-velocity blood flow in small vessels of the placenta by significantly reducing motion artifacts.1 Superb microvascular imaging with Doppler Luminance is the most up-to-date color Doppler, presenting three-dimensional (3D) SMI information on a two-dimensional (2D) gray-scale image by shading that is controlled by the amplitude of the Doppler signal.2 Several SMI studies have been conducted on normal and abnormal placentas using these techniques.1–10 Recently, more meticulous assessments of the placental microvasculature were reported on employing SMI with the application of an 18-MHz probe (PLI-1205BX, Canon Medical Systems, Tokyo, Japan).11–13
Here, the most up-to-date state-of-the-art SMI of normal and abnormal placental microvasculatures using an 18-MHz probe is presented. Present and future applications of this novel technique to assess normal and abnormal placentas in clinical practice are also considered.
NORMAL PLACENTA
Fifteen anterior implanted placentas at 16–40 weeks of gestation were evaluated with SMI with an 18-MHz probe. Smart 3D was used to reconstruct the spatial placental microvasculature.4,11
Placental Microvasculature
The tertiary stem villous vessels could be seen around 16 weeks (Fig. 1), and they showed increasing complexity after 16 weeks to term (Figs 1 to 5). Spiral arteries could be seen discharging blood into the intervillous space, and the terminal ends of these vessels suggested successful trophoblastic invasion (Figs 1, 2, 4, and 5). The increased density of the placental microvasculature was evident using SMI with an 18-MHz probe compared with that with conventional SMI (Figs 6 and 7).
Placental Baseline
The placental baseline between placenta and myometrium could be clearly identified at 16–40 weeks of gestation (Figs 8 to 12). The arcuate artery and decidual vessels were also evident using SMI with an 18-MHz probe.
SUBCHORIONIC HEMATOMA
In a case with vaginal bleeding at 12 weeks and 5 days of gestation, 2D sonography showed an extremely large subchorionic hematoma (Fig. 13). Conventional SMI and SD SMI revealed an avascular area in the placenta adjacent to the hematoma (Figs 14 and 15). Slightly increased echogenicity was noted in the placenta adjacent to the hematoma using 18-MHz 2D sonography, and decreased vascularity was clearly recognized in the same area using SMI with an 18-MHz probe (Fig. 16). Smart 3D using an 18-MHz probe demonstrated a few main stem villous vessels in the avascular area of the placenta, whereas tertiary stem villous vessels were identified in the normal-echogenicity placenta (Fig. 17).
CIRCUMVALLATE PLACENTA
A placenta with increased thickness and rolled up edges protruding into the uterine cavity was noted on a 2D sonographic image at a gestational age of 28 weeks and 5 days,2 and conventional SMI could visualize moderate intra-placental vessels (Fig. 18). Spatial relationships of intra-placental blood vessels were clearly noted using conventional smart 3D (Fig. 19). The placental microvasculature was clearer using 18-MHz SMI than conventional SMI (Fig. 20). The diagnosis could be confirmed with a gross specimen of the placenta after birth (Fig. 21).
PREVIOUS UTERINE FUNDAL INCISION
In a patient achieving pregnancy after a previous uterine fundal incision, at 30 weeks and 6 days of gestation,11 conventional 2D sonography failed to identify a uterine wall. Conversely, the modality of high-resolution SMI with an 18-MHz probe clearly depicted a very thin wall (Fig. 22). The placental baseline could be clearly presented. Also, there was no abnormal blood flow. During surgery, placental removal was possible without any adhesion. The membranous uterine wall at the fundal lesion could be clearly identified (Fig. 23).
PLACENTA ACCRETA SPECTRUM
Regarding the first case of placenta accreta spectrum (PAS) at 37 weeks and 4 days of gestation, placental baseline disruption and lack of a uterine wall were clearly noted using SMI with an 18-MHz probe (Fig. 24). Placenta accreta spectrum was identified intraoperatively (Fig. 25).
In the second case of PAS at a gestational age of 31 weeks and 4 days,2 the lower anterior segment of the uterus showed significant dilatation of decidual vessels (Fig. 26).
RETAINED PLACENTA WITH PLACENTA ACCRETA SPECTRUM
Regarding the first case,12 high-resolution SMI with an 18-MHz linear probe clearly revealed irregular minimal invasion by the retained placenta into the anterior myometrium, as well as disruption of decidual vessels at this pathological lesion with the retained placenta showing abnormal blood flow (Fig. 27).
In the second case,12 abundant blood flow was identified by conventional SMI in the placental bed next to the uterine wall (Figs 28 and 29). High-resolution SMI in conjunction with an 18-MHz probe clearly revealed myometrial loss anterior to fundal lesions (Fig. 30), and abnormally dilated, torturous, vessels invading up to the uterine serosa (snow storm-like appearance) (Fig. 31).
CONCLUSION
It is possible for SMI with an 18-MHz probe to clearly depict low-velocity blood flow in normal and abnormal placentas. However, SMI with an 18-MHz probe is markedly limited by shallow probe penetration.14 Thus, the probe’s sole use is for an anterior implanted placenta. Motion artifacts and noise resulting from fetal movements are also limitations, along with maternal respiratory movements and obesity. However, in both clinical practice and research, this modality may provide new knowledge regarding the pathophysiology of normal and abnormal placental microvasculatures.
References
1. Hasegawa J, Suzuki N. SMI for imaging of placental infarction. Placenta 2016;47:96–98. DOI: 10.1016/j.placenta.2016.08.092.
2. Hata T, Mori N, AboEllail MAM, et al. SMI with Doppler luminance in obstetrics. Donald School J Ultrasound Obstet Gynecol 2019;13(2):69–77. DOI: 10.5005/jp-journals-10009-1588.
3. Hasegawa J, Yamada H, Kawasaki E, et al. Application of superb micro-vascular imaging (SMI) in obstetrics. J Matern Fetal Neonatal Med 2018;31(2):261–263. DOI: 10.1080/14767058.2016.1278206.
4. Hata T, Kanenishi K, Yamamoto K, et al. Microvascular imaging of thick placenta with fetal growth restriction. Ultrasound Obstet Gynecol 2018;51(6):837–839. DOI: 10.1002/uog.18837.
5. Mack LM, Mastrobattista JM, Gandhi R, et al. Characterization of placental microvasculature using superb microvascular imaging. J Ultrasound Med 2019;38(9):2485–2491. DOI: 10.1002/jum.14919.
6. Furuya N, Hasegawa J, Homma C, et al. Novel ultrasound assessment of placental pathological function using superb microvascular imaging. J Matern Fetal Neonatal Med 2020. 1–4. DOI: 10.1080/14767058.2020.1795120.
7. Sainz JA, Carrera J, Borrero C, et al. Study of the development of placental microvascularity by Doppler SMI (superb microvascular imaging): a reality today. Ultrasound Med Biol 2020;46(12):3257–3267. DOI: 10.1016/j.ultrasmedbio.2020.08.017.
8. Inoue A, Horinouchi T, Yoshizato T, et al. Peculiar blood flow profiles among placental chorionic villous vessels of an abnormally thick placenta in a case of systemic lupus erythematosus characterized using microvascular imaging. J Obstet Gynaecol Res 2020(12). DOI: 10.1111/jog.14502.
9. Sun L, Li N, Jia L, et al. Comparison of superb microvascular imaging and conventional Doppler imaging techniques for evaluating placental microcirculation: a prospective study. Med Sci Monit 2020;10:e926215. DOI: 10.12659/MSM.926215.
10. Horinouchi T, Yoshizato T, Kojiro-Sanada S, et al. Missing decidual Doppler signals as a new diagnostic criterion for placenta accreta spectrum: a case described using superb microvascular imaging. J Obstet Gynaecol Res 2020(1). DOI: 10.1111/jog.14441.
11. Hata T, Mori N, AboEllail MAM, et al. Advances in color Doppler in obstetrics. J South Asian Feder Obst Gynae 2019;11(1):1–12. DOI: 10.5005/jp-journals-10006-1641.
12. Hata T, Hanaoka U, Mori A, et al. Superb microvascular imaging of retained placenta with placenta accreta spectrum. Donald School J Ultrasound Obstet Gynecol 2019;13(3):85–87. DOI: 10.5005/jp-journals-10009-1600.
13. Hasegawa J, Kurasaki A, Hata T, et al. Sono-histological findings of the placenta accreta spectrum. Ultrasound Obstet Gynecol 2019;54(5):705–707. DOI: 10.1002/uog.20207.
14. Hata T, Koyanagi A, Yamanishi T, et al. Superb microvascular imaging with Doppler luminance using 18-MHz probe to visualize fetal intra-abdominal blood vessels and organ microvasculature. J Perinat Med 2020;48(2):184–188. DOI: 10.1515/jpm-2019-0411.
________________________
© The Author(s). 2021 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.